GHL Interface PLM-pH/Redox-DigTemp GHL
  • New
€169.90
Aquael Thermometer Link OthersThermometer Link
  • New
€36.99
  • New
€284.00
Zoomed REPTISUN 5% UVB 15W 45cm ZM Terrarium lighting
  • On sale!
  • New
€39.90
Zoomed REPTISOIL 23L ZM Soil
  • On sale!
  • New
€39.90
Zoomed FILTER TURTLE CLEAN mediuml Pump
  • On sale!
  • New
€39.90
Zoomed VASQUE REPTI ROCK CORNER BOWL LARGE Accessories
  • On sale!
  • New
Zoomed VASQUE REPTI RAMP BOWL LARGE Accessories
  • On sale!
  • New
€44.90
Zoomed REPTISUN 10% UVB 18W Terrarium lighting
  • On sale!
  • New
€44.90
Zoomed REPTISUN 10% UVB 15W Terrarium lighting
  • On sale!
  • New
€44.90
Zoomed REPTISUN 10% UVB 36W Terrarium lighting
  • On sale!
  • New
€44.90
Zoomed REPTISUN 10% UVB 25W (to order x 12pc minimum) Terrarium lighting
  • On sale!
  • New
Zoomed REPTISUN 10% UVB 30W Terrarium lighting
  • On sale!
  • New
€44.90
Zoomed REPTISUN 10% UVB 24W 60cm Terrarium lighting
  • On sale!
  • New
€44.90
Zoomed CABLE CHAUF.25W REPTI HEAT ZM Heater
  • On sale!
  • New
€44.90
Zoomed REPTI BARK 26L -ZM Soil
  • On sale!
  • New
€44.90
Zoomed CERAMIC INFRARED 60W - ZM Heater
  • On sale!
  • New
€44.90
Zoomed LAMPE REPTISUN 5.0 COMPACT 26W Terrarium lighting
  • On sale!
  • New
€49.90
Zoomed CAVERNE wood resin TURTLE HUT GIANT Accessories
  • On sale!
  • New
      Maintenance-Kit Oxygen-Sensor
      Maintenance-Kit Oxygen-Sensor

      Maintenance-Kit Oxygen-Sensor

      Review (0)
      €147.00
      Tax Included
      Shipped under 15 days

      Maintenance-Kit Oxygen-Sensor

      Maintenance and repair set for Oxygen sensors
      (detailed instruction included in delivery) consisting of:

      Sand paper
      Pulp tissue
      Electrolyte solution 3x
      Membrane heads 3x

      A maintenance becomes then necessary if the membrane head is defective, the sensor can’t be calibrated anymore or if the setting time exceeds the specified value considerably.

      Quantity :
      >Earn 147 points/€2.94 Earn 147 points/€2.94 (Each €1.00 spent = 1 point, 1 point = €0.02 discount)
      Your cart will total 147 points that can be converted into a voucher of €2.94.
      • Secure paymentSecure payment CB or bank transfert
      • We send worldwide!We send worldwide! Register to see costs
      • Question?Question? Contact us, we answer quickly!

      It includes cleaning of the membrane, possible the change of the electrolyte solution, the exchange of the membran head and the cleaning of the electrode system.
      The maintenance interval depends on the particular measurement conditions, especially on the pollution degree of the measurement medium and the effect of disturbing substances, e.g. hydrogen sulfide, on the electrochemi-cal measurement system. To recover the full functional efficiency of the sensor in case of disturbances, it is recommended to proceed with the steps described in detail below:

      1. Cleaning of the membrane with a wet pulp.
      Rinse the membrane carefully with water without removing the membrane head and clean it with a wet pulp. If a new cali-bration is not possible afterwards or if the sensor data deviate significantly from the specification then the electrolyte solution and the membrane head have to be replaced.

      2. Changing electrolyte solution and membrane head

      Therefore unscrew the membrane head and examine the anode visually. Possibly the regeneration of the anode is necessary.

      3. Regeneration of the anode